Steel moment frame check with IPE and BOX
sazeh checks intermediate and special steel moment frames with IPE beams and box (BOX) columns from the .e2k file of an ETABS model against the steel code. For every beam and column the demand/capacity ratio under every load combination is computed and printed on the calculation sheet. The seismic load is built under the seismic code. Lateral-torsional buckling of beams is not checked: a beam is assessed as continuously braced by the slab.
What is checked
| Member | Check |
|---|---|
| IPE beam | Section compactness, flexure with the reduction for flange local buckling, shear and torsion |
| Box column | Compression, interaction of axial force with bending about both axes, local buckling of the walls, shear and torsion |
| Second-order effect | B1 for every column, and B2 for every storey from that storey's gravity load, shear and drift |
The column interaction is checked at the largest and the least axial force of the envelope, and the governing case is kept. The effective length factor of a column is taken as 1.0. The strength reduction factor for beam flexure and shear is 0.90.
Lateral-torsional buckling
Floor beams are assessed as continuously braced by the slab (Lb = 0, and Mn = Mp for a compact section), and the lateral-torsional buckling curve is not run in this version. A beam that no slab braces, such as a beam without a slab, has to be checked separately.
Torsion
Torsion of an IPE beam is assessed with the uniform (St Venant) part only, which ignores warping. A row that is met is therefore an approximation, not proof, and a row that is exceeded stays "deferred", not "not met".
What is not checked
- lateral-torsional buckling of beams;
- steel connections and the panel zone;
- strong column, weak beam in a steel frame (sazeh makes this check at concrete joints only);
- a steel member whose section is not an IPE beam or a box column, which appears on the sheet as "not designed" with the reason;
- a box with a slender web, whose row stays "deferred";
- concentrically braced frames, whose system row is not implemented.
How is the seismic compactness of box columns and IPE beams checked in a steel moment frame?
The steel code sets width-to-thickness limits for the members of a seismic moment frame that are stricter than the compactness limit for flexure. sazeh does not check these seismic compactness limits; that check stays with the engineer. What sazeh checks is the compactness limit for flexural strength:
| Section | Element | Compactness limit sazeh applies |
|---|---|---|
| IPE beam | Flange | b / 2tf ≤ 0.38·√(E/Fy) |
| IPE beam | Web | (h − 2tf) / tw ≤ 3.76·√(E/Fy) |
| Box column | Compression wall | (b − 3t) / t ≤ 1.12·√(E/Fy); non-compact up to 1.40·√(E/Fy) |
| Box column | Wall in bending (web) | Compact up to 2.42·√(E/Fy), non-compact up to 5.70·√(E/Fy) |
A non-compact IPE beam is reported as not met on the compactness row, and its flexural strength is reduced for flange local buckling. In a box column with a non-compact wall the reduced nominal moment is used in the interaction, and a box with a slender web stays "deferred".
Check this on your own model
Upload the .e2k file on the upload page. For every IPE beam the sheet prints the compactness status and the flexure, shear and torsion ratios, and for every box column the compression, interaction, shear and torsion ratios and the factors B1 and B2, with the governing combination. Seismic compactness limits, lateral-torsional buckling and connections are not checked on the sheet.
What happens when a member is not adequate?
Where a larger section can fix the failed clause, a corrected model with the new section and the list of changes to apply in ETABS is delivered. The final choice and the signature rest with the engineer.
Related pages
- Column checks: strong column, weak beam and P-M
- Reinforced-concrete design check
- Structural design: what is checked and what is not
- Limitations
Upload your ETABS .e2k model and get the calculation sheet.