Reinforced-concrete design check

sazeh checks intermediate and special reinforced-concrete moment frames, and the dual wall-frame system, from the .e2k file of an ETABS model against the reinforced-concrete code. For every concrete beam and column with a rectangular section, the required reinforcement and the demand/capacity ratio under every load combination are computed and printed on the calculation sheet. The seismic load is built under the seismic code.

What is checked

MemberCheck
BeamFlexure (Mu against φMn) and the required steel, the minimum and maximum steel ratio, shear, hoop spacing in the hinge zone, and torsion
ColumnAxial-moment (P-M) interaction, biaxial bending, shear, hoop spacing and slenderness (moment magnification)
JointStrong column, weak beam on nominal strengths: the sum of the column flexural strengths at least 1.2 times the sum of the beam flexural strengths
Shear wallIn-plane shear, flexure, vertical steel ratio and boundary element

Shear in a special frame

In a special moment frame the design shear of a beam is built from the probable moments at its two ends, not from the analysis shear alone. Over the plastic hinge length the concrete contribution to shear strength is taken as zero when the earthquake-induced shear is at least half of the required shear and the axial force is below Ag·fc/20. In an intermediate frame this rule does not apply and the concrete contribution stays.

Strength reduction factors

The strength reduction factor is 0.90 for tension-controlled flexure, 0.75 for shear and 0.65 for a tied column in the compression-controlled state, and between the two states it varies with the strain of the tension steel.

What is not checked

Does sazeh design the reinforcement or only check it?

For a beam, the flexural steel required by the governing moment is computed and printed. If the section in the model defines its reinforcement, that reinforcement is checked. For a column, the P-M curve is built with the reinforcement defined on the column section of the model, and with a default layout of eight 20 mm bars when the section defines none. Where a clause is not met and a larger section can fix it, a corrected model with the new section is delivered.

Are the results the same as in ETABS?

No. sazeh runs the analysis with its own engine, so a number can differ from the ETABS number. No formal comparison with a reference program has been made yet (limitations).

Related pages

Upload your ETABS .e2k model and get the calculation sheet.