What is the response modification factor of an intermediate concrete moment frame?

In table 3-4 of the seismic code, an intermediate reinforced-concrete moment frame has Ru = 5 and a deflection amplification factor Cd = 4.5. sazeh takes these values from table 3-4 for the system you choose on the form, and never infers Ru from the base shear coefficient written in the ETABS model. The seismic coefficient follows clause 3-3-1: C = A·B·I / Ru.

Factors of the systems sazeh applies

SystemRuCd
Intermediate concrete moment frame54.5
Special concrete moment frame7.55.5
Intermediate steel moment frame54
Special steel moment frame7.55.5
Dual system: intermediate concrete moment frame with special shear walls6.55

A system that is not in this table, such as a concentrically braced frame, does not borrow a neighbour's factor, and the rows that depend on it stay "deferred". sazeh also checks that the material of the frame agrees with the chosen row.

Worked example: a five-storey concrete building on soil type III

The example uses the same tables and formulas as sazeh. Assumptions: intermediate concrete moment frame, five storeys of 3.2 m (16 m in all), residential use, and a city in the very-high hazard band.

  1. A. The very-high band gives A = 0.35 (design base acceleration A).
  2. Empirical period. T = 0.05 × 16^0.9 ≈ 0.61 s (clause 3-3-3).
  3. B1. For soil type III in the very-high band, T0 = 0.15, Ts = 0.7 and S = 1.75. T lies between T0 and Ts, so B1 = S + 1 = 2.75.
  4. N. T < Ts, so N = 1 and B = B1·N = 2.75.
  5. I. Residential use is group 3, I = 1.0.
  6. C. C = 0.35 × 2.75 × 1.0 / 5 ≈ 0.193.
  7. Floor. 0.12·A·I = 0.042, below C, so it does not govern.

With a special concrete moment frame (Ru = 7.5) the same building gets C ≈ 0.128. A different storey height or soil type changes T and B1, and so C.

Where does this go in ETABS?

ETABS does not take Ru directly: the base shear coefficient C is entered on a seismic load pattern of the User Coefficient type, with the height exponent k beside it. Cd is not part of C; it is used in the drift check. ETABS does not write the storey forces of such a pattern into the .e2k file, so sazeh builds the equivalent static seismic load itself from A, the soil type, the system and the seismic weight of the model.

Check this on your own model

Upload the .e2k file on the upload page and choose the design base acceleration, the soil type and the structural system. The sheet prints Ru and Cd of the system, B1, N, C and the base shear floor, each with its clause number, and compares the base shear of the model's analysis with the code base shear. The full method is on the base shear page.

What if the seismic coefficient of my model differs from sazeh's?

sazeh does not adopt the model's number; it builds the seismic load from its own tabulated factors. A difference usually comes from the system, the soil type, the hazard band or the height, and the sheet prints all of these inputs so that the cause can be found.