What should a structural calculation sheet contain?

A complete calculation sheet shows where every number comes from: the assumptions and the code editions, the site parameters, the structural system, the materials and sections, the gravity loads and load combinations, the seismic weight, the seismic coefficient and its distribution over the height, the global checks such as drift, torsion and overturning, the design of beams and columns with clause numbers, and the support reactions for the foundation designer. A sheet that holds only the member design output, and does not show the source of A, the seismic weight and the seismic coefficient, is usually judged incomplete.

The sections of the sheet sazeh delivers

The sheet of sazeh has a fixed order, so that an engineer finds each part in its usual place:

SectionContent
Assumptions and code editionAnalysis method, cracked-stiffness basis, accidental torsion and vertical component applied or not, and the edition of every code
Geometry, system, materials and sectionsStoreys, the structural system with Ru and Cd, materials and the sections used
Gravity loading and load combinationsThe loads of the loading code and the combinations
Seismic weight, seismic coefficient and vertical distributionW, A with its source, B1, N, C and the force of every storey
Overturning and driftThe overturning safety factor, and the drift of every storey with the governing joint and combination
Concrete beams and columnsBeam flexural steel, shear and hoops; column P-M, biaxial bending, shear and hoops
Strong column, weak beam, and steel sectionsThe ratio of every joint, and the checks of IPE beams and box columns
Support reactions and wall pier forcesFor the foundation and wall designers
Deferred rows and design coverageWhat got no verdict and why, and the count of members not designed
Quantities, corrected model and actions in ETABSWeight and volume, section changes, and the list of fixes named after the ETABS windows
Supplementary seismic checksPenthouse, torsion, vertical component and analysis method

The sheet of sazeh does not contain foundation design, slab and punching design, steel connections or rebar shop drawings. If a project needs them, they have to be prepared separately.

Common ETABS modelling mistakes that plan checkers catch

These mistakes are found in ETABS models more often than others, and sazeh has a separate row for each of them:

Common mistakeRow on the sazeh sheet
The mass source counts only the dead load, or too small a share of the live loadMass source against the code table
The seismic load patterns carry no load, because User Coefficient forces are not written into the .e2k fileThe seismic-load-present row, and the equivalent static load that sazeh builds
Accidental torsion is assumed but no pattern carries a momentThe accidental torsion row, clause 3-3-7
Drift of a torsionally irregular storey is read at the centre of massDrift at the diaphragm corner
The 100-30 combination is incomplete, for example with one sign only for the 30% componentThe orthogonal-combination row, with all four sign pairs
The structural system or Ru does not match the material of the frameThe system and material row of table 3-4
Too few modes to reach 90% of the massThe modal mass row
The spectrum in the model does not match the site and soil typeThe comparison of the model's spectrum function with the code spectrum
A penthouse is not declaredThe penthouse row, which stays "deferred" until it is declared

These are integrity checks of the model, and they are part of the check sazeh makes against its one national code set. sazeh does not check a building against any other country's codes; to ask for another code set, use the request page.

How do I get through the calculations of a six-storey residential building faster?

Most of the time goes into repeated checks: reading the mass source, building the seismic coefficient, extracting the corner drifts and comparing demand/capacity ratios. For a six-storey building keep two points in mind from the start. The drift limit for a building of more than 5 storeys is 0.02 of the storey height. The equivalent static method alone is allowed above 3 storeys only below 50 m and without torsional, mass or soft-storey irregularity. Then check the model with sazeh, so that these checks are made in one pass and only the rows that are not met or are deferred need your review.

Check this on your own model

Upload the .e2k file on the upload page and choose the design base acceleration, the soil type and the structural system. The sheet opens with the overall result, counts in members, joints and storeys, and prints the rows of the table above with their clause numbers. Its last section turns the necessary fixes into actions in the ETABS windows.

Can the sheet be submitted as it is?

The sheet is a review aid, and the signature and the responsibility rest with the engineer. The analysis of sazeh has not yet been formally compared with a reference program (limitations).

Related pages

Upload your ETABS .e2k model and get the calculation sheet.

Start the calculation